AICON-BIO® GS AntiQ qPCR SYBR Green Fast Mix (Low ROX Premixed)

$318.50 – $637.00

Catalog NumberUnit SizePrice
AISQ411-55 × 1.0 mL$455.00 $318.50 (30% off)
AISQ411-1010 × 1.0 mL$910.00 $637.00 (30% off)

Storage: −20 °C, protect from light; 4 °C for up to 1 month

Product image for reference only; actual product may vary.

SKU: AISQ411 Category:
Description

A 2× SYBR Green qPCR master mix with an antibody-modified hot-start polymerase and premixed ROX II (Low) reference dye, for instruments that require low-ROX normalization.

Features & Benefits

  • Low ROX premixed — ready for instruments requiring low-ROX normalization
  • Hot start — antibody-blocked polymerase for specificity
  • Fast — compatible with fast cycling
  • High sensitivity — efficiency 90–110%

Specifications

DetectionSYBR Green I dye
PolymeraseAntibody-modified hot-start Taq
Concentration2×
Reference dyeROX II (Low) premixed
Reaction volume20 µL (10–50 µL)
Reactions500 × 20 µL
CyclingStandard or fast
Storage−20 °C, protect from light; 4 °C for up to 1 month
ShippingBlue ice

For Research Use Only. Not for use in diagnostic procedures.

See the Instructions for Use and Safety Data Sheet tabs for protocols and safety information.

Instructions for Use

AICON-BIO® GS AntiQ qPCR SYBR Green Fast Mix (Low ROX Premixed) — Instructions for Use

Cat. No. AISQ411 · 5 × 1.0 mL · For Research Use Only. Not for use in diagnostic procedures.

1. Description

A 2× SYBR Green qPCR master mix with an antibody-modified hot-start polymerase and premixed ROX II (Low) reference dye, for instruments that require low-ROX normalization.

2. Kit Contents and Storage

ComponentQuantityStorage
GS AntiQ qPCR SYBR Green Fast Mix (Low ROX Premixed)5 × 1.0 mL−20 °C, protect from light

Stable for 12 months from date of manufacture when stored as directed.

3. Reaction Setup

ComponentVolume
2× master mix10 µL
Forward primer (10 µM)0.4 µL (200 nM final)
Reverse primer (10 µM)0.4 µL (200 nM final)
Template (cDNA or DNA)1–2 µL
Nuclease-free waterto 20 µL

4. Thermal Program

StepTemperatureTimeCycles
Polymerase activation95 °C30 s1
Denaturation95 °C5–10 s40
Annealing/extension (data collection)60 °C30 s
Melt curve65 → 95 °Cinstrument default1

5. Procedure

  1. Thaw the mix on ice, protected from light; mix gently and spin briefly.
  2. Prepare a master mix of all components except template; dispense into plate wells, then add template.
  3. Seal, spin the plate briefly and run the program below. Always include a melt curve to confirm specificity.
  4. Analyze with the instrument software; include no-template controls and a standard curve or reference genes.

6. Notes

  • Design amplicons of 80–200 bp; primer Tm 58–62 °C.
  • Protect from light; avoid repeated freeze–thaw. Stable at 4 °C for 1 month.
  • Suitable for ABI 7500, ViiA 7, QuantStudio and other instruments requiring low ROX; not for instruments requiring high ROX.

7. Troubleshooting

ProblemPossible causeSolution
Late Ct or no amplificationPoor template quality; inhibitors; suboptimal primersCheck RNA/DNA quality; dilute template; redesign primers (amplicon 80–200 bp)
Multiple melt peaksPrimer-dimers or non-specific productRaise annealing temperature to 62–64 °C; lower primer to 100–200 nM
Signal in NTCContamination or primer-dimersUse fresh reagents and filter tips; check melt curve
High variation between replicatesPipetting error; bubblesUse master mixes; spin plate briefly before run

Aicon Biotech Inc. · 8194 SW Durham Rd, Tigard, OR 97224, USA · Tel 503-430-5188 · www.aiconbiotech.com

Safety Data Sheet

Safety Data Sheet — AICON-BIO® GS AntiQ qPCR SYBR Green Fast Mix (Low ROX Premixed)

Prepared per OSHA HCS (29 CFR 1910.1200) and GHS. Revision date: 2026-11-24 · Version 1.0

Section 1 — Identification

  • Product: AICON-BIO® GS AntiQ qPCR SYBR Green Fast Mix (Low ROX Premixed), Cat. No. AISQ411
  • Use: Laboratory research reagent. For Research Use Only. Not for use in diagnostic procedures.
  • Supplier: Aicon Biotech Inc. · 8194 SW Durham Rd, Tigard, OR 97224, USA · Tel 503-430-5188 · www.aiconbiotech.com
  • Emergency telephone: 503-430-5188 (business hours)

Section 2 — Hazard(s) Identification

Not a hazardous substance or mixture according to OSHA HCS 2012 / GHS. No pictogram, signal word or hazard statement required. May cause mild eye irritation on contact.

Section 3 — Composition

IngredientCAS No.Concentration
Glycerol56-81-5< 20%
Tris-HCl1185-53-1< 1%
Potassium chloride7447-40-7< 1%
Magnesium chloride7786-30-3< 0.1%
dNTP mixture—< 0.5%
Hot-start DNA polymerase and antibody (proprietary)—< 0.1%
SYBR Green I163795-75-3< 0.01%
ROX reference dye—< 0.01%
Water7732-18-5Balance

Section 4 — First-Aid Measures

  • Eyes: Rinse with water for at least 15 min. Get medical attention if irritation persists.
  • Skin: Wash with soap and water.
  • Inhalation: Move to fresh air.
  • Ingestion: Rinse mouth. Get medical advice if unwell.

Section 5 — Fire-Fighting Measures

Not flammable. Use extinguishing media suitable for the surrounding fire. Thermal decomposition may release carbon and nitrogen oxides.

Section 6 — Accidental Release Measures

Wear gloves and eye protection. Absorb with inert material and dispose of as laboratory waste.

Section 7 — Handling and Storage

Follow good laboratory practice. Storage: −20 °C, protect from light; 4 °C for up to 1 month. Incompatible: strong oxidizing agents.

Section 8 — Exposure Controls / Personal Protection

No exposure limits established. Safety glasses, nitrile gloves, lab coat. General laboratory ventilation.

Section 9 — Physical and Chemical Properties

Liquid; colorless; viscous (glycerol); miscible with water; not flammable.

Section 10 — Stability and Reactivity

Stable under recommended storage. Avoid strong oxidizers and excessive heat.

Section 11 — Toxicological Information

No data for the mixture; not classified based on component concentrations. No component is listed as a carcinogen by IARC, NTP or OSHA.

Section 12 — Ecological Information

No data. Not expected to be harmful at the quantities used.

Section 13 — Disposal

Dispose of in accordance with local, state and federal regulations.

Section 14 — Transport Information

Not regulated as a dangerous good (DOT, IATA, IMDG).

Section 15 — Regulatory Information

OSHA: not hazardous under 29 CFR 1910.1200. TSCA: for research and development use only, under the supervision of a technically qualified individual.

Section 16 — Other Information

Revision date 2026-11-24, Version 1.0. The information above is believed to be accurate but is not all-inclusive and should be used only as a guide. Aicon Biotech Inc. shall not be held liable for any damage resulting from handling or contact with this product. For Research Use Only. Not for use in diagnostic procedures.

Reviews

There are no reviews yet.

Only logged in customers who have purchased this product may leave a review.