AICON-BIO® Nuclease-Free Water (not DEPC-treated)
$69.00 – $129.00
| Catalog Number | Unit Size |
| AIDW101 | 1 × 500 mL / 10 × 50 mL |
Storage: Room temperature (15–30 °C)
Product image for reference only; actual product may vary.
Molecular biology grade water, deionized, 0.22 µm filtered into the final bottle and autoclaved. Ready to use with no preparation, mixing or autoclaving required. Every lot is tested for RNase, exonuclease and non-specific endonuclease activity. Not DEPC-treated, so there is no residual DEPC to interfere with sensitive applications such as oocyte microinjection or in vitro transcription.
Features & Benefits
- Lot-tested — free of RNase, DNase (endo- and exonuclease) and protease activity
- Not DEPC-treated — no residual DEPC carryover
- Ready to use — deionized, filtered and autoclaved in the final container
- Room-temperature storage and shipping — no cold chain
- Two formats — one 500 mL bottle, or ten 50 mL bottles to limit contamination risk
Specifications
| Grade | Molecular biology |
| Purification | Deionized, 0.22 µm membrane-filtered, autoclaved |
| Treatment | Not DEPC-treated |
| pH | 6.0–8.0 |
| Resistivity | ≥ 18.2 MΩ·cm at source |
| Quality control | No detectable RNase, DNase or protease activity; free of human and E. coli DNA |
| Pack sizes | 1 × 500 mL; 10 × 50 mL |
| Storage | Room temperature (15–30 °C) |
| Shipping | Ambient |
For Research Use Only. Not for use in diagnostic procedures.
See the Instructions for Use and Safety Data Sheet tabs for protocols and safety information.
AICON-BIO® Nuclease-Free Water (not DEPC-treated) — Instructions for Use
Cat. No. AIDW101 · 1 × 500 mL / 10 × 50 mL · For Research Use Only. Not for use in diagnostic procedures.
1. Description
Molecular biology grade water, deionized, 0.22 µm filtered into the final bottle and autoclaved. Ready to use with no preparation, mixing or autoclaving required. Every lot is tested for RNase, exonuclease and non-specific endonuclease activity. Not DEPC-treated, so there is no residual DEPC to interfere with sensitive applications such as oocyte microinjection or in vitro transcription.
2. Contents and Storage
| Component | Quantity | Storage |
|---|---|---|
| Nuclease-Free Water | 1 × 500 mL or 10 × 50 mL | Room temperature |
Stable for 12 months from date of manufacture when stored as directed.
3. Typical Use
| Application | Amount |
|---|---|
| PCR and qPCR reaction make-up | To final volume |
| Resuspension of primers and oligonucleotides | As required |
| Elution of purified DNA or RNA | 30–100 µL |
| Dilution of DNA/RNA samples and standards | As required |
| Enzyme reaction make-up (restriction digest, ligation, IVT) | To final volume |
4. Procedure
- Open the bottle only in a clean area; wear gloves to prevent RNase contamination from skin.
- Pour or pipette the volume needed using a sterile, nuclease-free pipette or tip. Never pipette directly from the stock bottle with a used tip.
- Recap immediately after use.
- For RNA work, dispense single-use aliquots into sterile nuclease-free tubes rather than returning to the stock bottle.
5. Notes
- Not sterile for injection or clinical use; for laboratory research only.
- Do not autoclave again — repeated autoclaving can introduce contaminants from the vessel.
- Once opened, the 500 mL bottle should be used within 6 months; the 50 mL bottles are intended for single-project use.
- Discard any bottle showing turbidity or particulates.
6. Troubleshooting
| Problem | Possible cause | Solution |
|---|---|---|
| RNA degrades after dilution | RNase introduced from tips, gloves or the bench | Use filter tips and fresh gloves; aliquot the water; decontaminate surfaces |
| Unexpected PCR amplification in no-template control | Contamination introduced during dispensing | Open a fresh 50 mL bottle; use a dedicated pre-PCR area |
| Turbidity in the bottle | Microbial growth after a contaminated withdrawal | Discard the bottle; never return unused water |
Aicon Biotech Inc. · 8194 SW Durham Rd, Tigard, OR 97224, USA · Tel 503-430-5188 · www.aiconbiotech.com
Safety Data Sheet — AICON-BIO® Nuclease-Free Water (not DEPC-treated)
Prepared per OSHA HCS (29 CFR 1910.1200) and GHS. Revision date: 2026-11-24 · Version 1.0
Section 1 — Identification
- Product: AICON-BIO® Nuclease-Free Water (not DEPC-treated), Cat. No. AIDW101
- Use: Laboratory research reagent. For Research Use Only. Not for use in diagnostic procedures.
- Supplier: Aicon Biotech Inc. · 8194 SW Durham Rd, Tigard, OR 97224, USA · Tel 503-430-5188 · www.aiconbiotech.com
- Emergency telephone: 503-430-5188 (business hours)
Section 2 — Hazard(s) Identification
Not a hazardous substance or mixture according to OSHA HCS 2012 / GHS. No pictogram, signal word or hazard statement required. May cause mild eye irritation on contact.
Section 3 — Composition
| Ingredient | CAS No. | Concentration |
|---|---|---|
| Water | 7732-18-5 | 100% |
Section 4 — First-Aid Measures
- Eyes: Rinse with water for at least 15 min. Get medical attention if irritation persists.
- Skin: Wash with soap and water.
- Inhalation: Move to fresh air.
- Ingestion: Rinse mouth. Get medical advice if unwell.
Section 5 — Fire-Fighting Measures
Not flammable. Use extinguishing media suitable for the surrounding fire. Thermal decomposition may release carbon and nitrogen oxides.
Section 6 — Accidental Release Measures
Wear gloves and eye protection. Absorb with inert material and dispose of as laboratory waste.
Section 7 — Handling and Storage
Follow good laboratory practice. Storage: Room temperature (15–30 °C). Incompatible: strong oxidizing agents.
Section 8 — Exposure Controls / Personal Protection
No exposure limits established. Safety glasses, nitrile gloves, lab coat. General laboratory ventilation.
Section 9 — Physical and Chemical Properties
Liquid; colorless; viscous (glycerol); miscible with water; not flammable.
Section 10 — Stability and Reactivity
Stable under recommended storage. Avoid strong oxidizers and excessive heat.
Section 11 — Toxicological Information
No data for the mixture; not classified based on component concentrations. No component is listed as a carcinogen by IARC, NTP or OSHA.
Section 12 — Ecological Information
No data. Not expected to be harmful at the quantities used.
Section 13 — Disposal
Dispose of in accordance with local, state and federal regulations.
Section 14 — Transport Information
Not regulated as a dangerous good (DOT, IATA, IMDG).
Section 15 — Regulatory Information
OSHA: not hazardous under 29 CFR 1910.1200. TSCA: for research and development use only, under the supervision of a technically qualified individual.
Section 16 — Other Information
Revision date 2026-11-24, Version 1.0. The information above is believed to be accurate but is not all-inclusive and should be used only as a guide. Aicon Biotech Inc. shall not be held liable for any damage resulting from handling or contact with this product. For Research Use Only. Not for use in diagnostic procedures.
Only logged in customers who have purchased this product may leave a review.

Reviews
There are no reviews yet.