AICON-BIO® MgCl₂ Solution (25 mM) for PCR
$44.00
| Catalog Number | Unit Size |
| AIMG101 | 8 × 1.25 mL |
Storage: −20 °C (non-frost-free freezer)
Product image for reference only; actual product may vary.
A 0.22 µm membrane-filtered 25 mM magnesium chloride solution for optimizing the Mg²⁺ concentration of PCR and other enzymatic reactions. Magnesium is the single most influential variable in a PCR: too little gives weak or no product, too much gives non-specific bands. Supplied in eight separate 1.25 mL tubes so a titration series can be run without risking the whole stock.
Features & Benefits
- Titration-ready — 25 mM stock gives 0.5–5 mM final in 1 mM steps
- 0.22 µm filtered
- Nuclease-free — free of endonucleases, exonucleases, RNases and phosphatases
- Eight separate tubes — 10 mL total, twice the volume of the common 4 × 1.25 mL format
- Universal — works with Taq, hot-start Taq, proofreading and long-range enzymes
Specifications
| Composition | 25 mM magnesium chloride in water |
| Pack size | 8 × 1.25 mL (10 mL total) |
| Filtration | 0.22 µm membrane |
| Quality control | Free of endodeoxyribonuclease, exodeoxyribonuclease, ribonuclease and phosphatase activity |
| Typical working range | 1.5–4.0 mM Mg²⁺ final |
| Storage | −20 °C (non-frost-free freezer) |
| Shipping | Blue ice |
For Research Use Only. Not for use in diagnostic procedures.
See the Instructions for Use and Safety Data Sheet tabs for protocols and safety information.
AICON-BIO® MgCl₂ Solution (25 mM) for PCR — Instructions for Use
Cat. No. AIMG101 · 8 × 1.25 mL · For Research Use Only. Not for use in diagnostic procedures.
1. Description
A 0.22 µm membrane-filtered 25 mM magnesium chloride solution for optimizing the Mg²⁺ concentration of PCR and other enzymatic reactions. Magnesium is the single most influential variable in a PCR: too little gives weak or no product, too much gives non-specific bands. Supplied in eight separate 1.25 mL tubes so a titration series can be run without risking the whole stock.
2. Contents and Storage
| Component | Quantity | Storage |
|---|---|---|
| MgCl₂ Solution, 25 mM | 8 × 1.25 mL | −20 °C |
Stable for 12 months from date of manufacture when stored as directed.
3. Typical Use
| Application | Amount |
|---|---|
| Final Mg²⁺ 1.5 mM in 50 µL | 3.0 µL |
| Final Mg²⁺ 2.0 mM in 50 µL | 4.0 µL |
| Final Mg²⁺ 2.5 mM in 50 µL | 5.0 µL |
| Final Mg²⁺ 3.0 mM in 50 µL | 6.0 µL |
| Final Mg²⁺ 4.0 mM in 50 µL | 8.0 µL |
4. Procedure
- Check whether your 10× PCR buffer already contains MgCl₂. If it does, the buffer alone usually gives 1.5–2.0 mM final; add this solution only to go higher.
- Thaw one tube, vortex and spin down briefly.
- For a first attempt with a new primer pair, run a titration at 1.5, 2.0, 2.5 and 3.0 mM final Mg²⁺ and compare the yield and specificity on a gel.
- Add the volume from the table above per 50 µL reaction; scale proportionally for other reaction volumes.
- Return the tube to −20 °C after use.
5. Notes
- dNTPs chelate magnesium: roughly 200 µM of total dNTP ties up 200 µM Mg²⁺. If you raise the dNTP concentration, raise the Mg²⁺ to match.
- EDTA carried over in the template also chelates magnesium. Elute DNA in water or low-EDTA buffer (0.1 mM) for best results.
- Store in a non-frost-free freezer; frost-free cycles concentrate the solution through repeated thawing.
6. Troubleshooting
| Problem | Possible cause | Solution |
|---|---|---|
| Weak or no product | Mg²⁺ too low, or chelated by EDTA/dNTP | Raise in 0.5 mM steps; elute template in water |
| Smeared or multiple bands | Mg²⁺ too high | Lower in 0.5 mM steps; raise the annealing temperature |
| Works for one primer pair but not another | Optimum Mg²⁺ is primer-dependent | Titrate separately for each assay |
| Results drift over time | Solution concentrated by freeze–thaw in a frost-free freezer | Use a non-frost-free freezer; open a fresh tube |
Aicon Biotech Inc. · 8194 SW Durham Rd, Tigard, OR 97224, USA · Tel 503-430-5188 · www.aiconbiotech.com
Safety Data Sheet — AICON-BIO® MgCl₂ Solution (25 mM) for PCR
Prepared per OSHA HCS (29 CFR 1910.1200) and GHS. Revision date: 2026-11-24 · Version 1.0
Section 1 — Identification
- Product: AICON-BIO® MgCl₂ Solution (25 mM) for PCR, Cat. No. AIMG101
- Use: Laboratory research reagent. For Research Use Only. Not for use in diagnostic procedures.
- Supplier: Aicon Biotech Inc. · 8194 SW Durham Rd, Tigard, OR 97224, USA · Tel 503-430-5188 · www.aiconbiotech.com
- Emergency telephone: 503-430-5188 (business hours)
Section 2 — Hazard(s) Identification
Not a hazardous substance or mixture according to OSHA HCS 2012 / GHS. No pictogram, signal word or hazard statement required. May cause mild eye irritation on contact.
Section 3 — Composition
| Ingredient | CAS No. | Concentration |
|---|---|---|
| Magnesium chloride | 7786-30-3 | 0.24% (25 mM) |
| Water | 7732-18-5 | Balance |
Section 4 — First-Aid Measures
- Eyes: Rinse with water for at least 15 min. Get medical attention if irritation persists.
- Skin: Wash with soap and water.
- Inhalation: Move to fresh air.
- Ingestion: Rinse mouth. Get medical advice if unwell.
Section 5 — Fire-Fighting Measures
Not flammable. Use extinguishing media suitable for the surrounding fire. Thermal decomposition may release carbon and nitrogen oxides.
Section 6 — Accidental Release Measures
Wear gloves and eye protection. Absorb with inert material and dispose of as laboratory waste.
Section 7 — Handling and Storage
Follow good laboratory practice. Storage: −20 °C (non-frost-free freezer). Incompatible: strong oxidizing agents.
Section 8 — Exposure Controls / Personal Protection
No exposure limits established. Safety glasses, nitrile gloves, lab coat. General laboratory ventilation.
Section 9 — Physical and Chemical Properties
Liquid; colorless; viscous (glycerol); miscible with water; not flammable.
Section 10 — Stability and Reactivity
Stable under recommended storage. Avoid strong oxidizers and excessive heat.
Section 11 — Toxicological Information
No data for the mixture; not classified based on component concentrations. No component is listed as a carcinogen by IARC, NTP or OSHA.
Section 12 — Ecological Information
No data. Not expected to be harmful at the quantities used.
Section 13 — Disposal
Dispose of in accordance with local, state and federal regulations.
Section 14 — Transport Information
Not regulated as a dangerous good (DOT, IATA, IMDG).
Section 15 — Regulatory Information
OSHA: not hazardous under 29 CFR 1910.1200. TSCA: for research and development use only, under the supervision of a technically qualified individual.
Section 16 — Other Information
Revision date 2026-11-24, Version 1.0. The information above is believed to be accurate but is not all-inclusive and should be used only as a guide. Aicon Biotech Inc. shall not be held liable for any damage resulting from handling or contact with this product. For Research Use Only. Not for use in diagnostic procedures.
Only logged in customers who have purchased this product may leave a review.

Reviews
There are no reviews yet.