AICON-BIO® MgCl₂ Solution (25 mM) for PCR

$44.00

Catalog NumberUnit Size
AIMG1018 × 1.25 mL

Storage: −20 °C (non-frost-free freezer)

Product image for reference only; actual product may vary.

SKU: AIMG101 Category:
Description

A 0.22 µm membrane-filtered 25 mM magnesium chloride solution for optimizing the Mg²⁺ concentration of PCR and other enzymatic reactions. Magnesium is the single most influential variable in a PCR: too little gives weak or no product, too much gives non-specific bands. Supplied in eight separate 1.25 mL tubes so a titration series can be run without risking the whole stock.

Features & Benefits

  • Titration-ready — 25 mM stock gives 0.5–5 mM final in 1 mM steps
  • 0.22 µm filtered
  • Nuclease-free — free of endonucleases, exonucleases, RNases and phosphatases
  • Eight separate tubes — 10 mL total, twice the volume of the common 4 × 1.25 mL format
  • Universal — works with Taq, hot-start Taq, proofreading and long-range enzymes

Specifications

Composition25 mM magnesium chloride in water
Pack size8 × 1.25 mL (10 mL total)
Filtration0.22 µm membrane
Quality controlFree of endodeoxyribonuclease, exodeoxyribonuclease, ribonuclease and phosphatase activity
Typical working range1.5–4.0 mM Mg²⁺ final
Storage−20 °C (non-frost-free freezer)
ShippingBlue ice

For Research Use Only. Not for use in diagnostic procedures.

See the Instructions for Use and Safety Data Sheet tabs for protocols and safety information.

Instructions for Use

AICON-BIO® MgCl₂ Solution (25 mM) for PCR — Instructions for Use

Cat. No. AIMG101 · 8 × 1.25 mL · For Research Use Only. Not for use in diagnostic procedures.

1. Description

A 0.22 µm membrane-filtered 25 mM magnesium chloride solution for optimizing the Mg²⁺ concentration of PCR and other enzymatic reactions. Magnesium is the single most influential variable in a PCR: too little gives weak or no product, too much gives non-specific bands. Supplied in eight separate 1.25 mL tubes so a titration series can be run without risking the whole stock.

2. Contents and Storage

ComponentQuantityStorage
MgCl₂ Solution, 25 mM8 × 1.25 mL−20 °C

Stable for 12 months from date of manufacture when stored as directed.

3. Typical Use

ApplicationAmount
Final Mg²⁺ 1.5 mM in 50 µL3.0 µL
Final Mg²⁺ 2.0 mM in 50 µL4.0 µL
Final Mg²⁺ 2.5 mM in 50 µL5.0 µL
Final Mg²⁺ 3.0 mM in 50 µL6.0 µL
Final Mg²⁺ 4.0 mM in 50 µL8.0 µL

4. Procedure

  1. Check whether your 10× PCR buffer already contains MgCl₂. If it does, the buffer alone usually gives 1.5–2.0 mM final; add this solution only to go higher.
  2. Thaw one tube, vortex and spin down briefly.
  3. For a first attempt with a new primer pair, run a titration at 1.5, 2.0, 2.5 and 3.0 mM final Mg²⁺ and compare the yield and specificity on a gel.
  4. Add the volume from the table above per 50 µL reaction; scale proportionally for other reaction volumes.
  5. Return the tube to −20 °C after use.

5. Notes

  • dNTPs chelate magnesium: roughly 200 µM of total dNTP ties up 200 µM Mg²⁺. If you raise the dNTP concentration, raise the Mg²⁺ to match.
  • EDTA carried over in the template also chelates magnesium. Elute DNA in water or low-EDTA buffer (0.1 mM) for best results.
  • Store in a non-frost-free freezer; frost-free cycles concentrate the solution through repeated thawing.

6. Troubleshooting

ProblemPossible causeSolution
Weak or no productMg²⁺ too low, or chelated by EDTA/dNTPRaise in 0.5 mM steps; elute template in water
Smeared or multiple bandsMg²⁺ too highLower in 0.5 mM steps; raise the annealing temperature
Works for one primer pair but not anotherOptimum Mg²⁺ is primer-dependentTitrate separately for each assay
Results drift over timeSolution concentrated by freeze–thaw in a frost-free freezerUse a non-frost-free freezer; open a fresh tube

Aicon Biotech Inc. · 8194 SW Durham Rd, Tigard, OR 97224, USA · Tel 503-430-5188 · www.aiconbiotech.com

Safety Data Sheet

Safety Data Sheet — AICON-BIO® MgCl₂ Solution (25 mM) for PCR

Prepared per OSHA HCS (29 CFR 1910.1200) and GHS. Revision date: 2026-11-24 · Version 1.0

Section 1 — Identification

  • Product: AICON-BIO® MgCl₂ Solution (25 mM) for PCR, Cat. No. AIMG101
  • Use: Laboratory research reagent. For Research Use Only. Not for use in diagnostic procedures.
  • Supplier: Aicon Biotech Inc. · 8194 SW Durham Rd, Tigard, OR 97224, USA · Tel 503-430-5188 · www.aiconbiotech.com
  • Emergency telephone: 503-430-5188 (business hours)

Section 2 — Hazard(s) Identification

Not a hazardous substance or mixture according to OSHA HCS 2012 / GHS. No pictogram, signal word or hazard statement required. May cause mild eye irritation on contact.

Section 3 — Composition

IngredientCAS No.Concentration
Magnesium chloride7786-30-30.24% (25 mM)
Water7732-18-5Balance

Section 4 — First-Aid Measures

  • Eyes: Rinse with water for at least 15 min. Get medical attention if irritation persists.
  • Skin: Wash with soap and water.
  • Inhalation: Move to fresh air.
  • Ingestion: Rinse mouth. Get medical advice if unwell.

Section 5 — Fire-Fighting Measures

Not flammable. Use extinguishing media suitable for the surrounding fire. Thermal decomposition may release carbon and nitrogen oxides.

Section 6 — Accidental Release Measures

Wear gloves and eye protection. Absorb with inert material and dispose of as laboratory waste.

Section 7 — Handling and Storage

Follow good laboratory practice. Storage: −20 °C (non-frost-free freezer). Incompatible: strong oxidizing agents.

Section 8 — Exposure Controls / Personal Protection

No exposure limits established. Safety glasses, nitrile gloves, lab coat. General laboratory ventilation.

Section 9 — Physical and Chemical Properties

Liquid; colorless; viscous (glycerol); miscible with water; not flammable.

Section 10 — Stability and Reactivity

Stable under recommended storage. Avoid strong oxidizers and excessive heat.

Section 11 — Toxicological Information

No data for the mixture; not classified based on component concentrations. No component is listed as a carcinogen by IARC, NTP or OSHA.

Section 12 — Ecological Information

No data. Not expected to be harmful at the quantities used.

Section 13 — Disposal

Dispose of in accordance with local, state and federal regulations.

Section 14 — Transport Information

Not regulated as a dangerous good (DOT, IATA, IMDG).

Section 15 — Regulatory Information

OSHA: not hazardous under 29 CFR 1910.1200. TSCA: for research and development use only, under the supervision of a technically qualified individual.

Section 16 — Other Information

Revision date 2026-11-24, Version 1.0. The information above is believed to be accurate but is not all-inclusive and should be used only as a guide. Aicon Biotech Inc. shall not be held liable for any damage resulting from handling or contact with this product. For Research Use Only. Not for use in diagnostic procedures.

Reviews

There are no reviews yet.

Only logged in customers who have purchased this product may leave a review.