AICON-BIO® Nuclease-Free Water (not DEPC-treated)

$69.00 – $129.00

Catalog NumberUnit Size
AIDW1011 × 500 mL / 10 × 50 mL

Storage: Room temperature (15–30 °C)

Product image for reference only; actual product may vary.

SKU: AIDW101 Category:
Description

Molecular biology grade water, deionized, 0.22 µm filtered into the final bottle and autoclaved. Ready to use with no preparation, mixing or autoclaving required. Every lot is tested for RNase, exonuclease and non-specific endonuclease activity. Not DEPC-treated, so there is no residual DEPC to interfere with sensitive applications such as oocyte microinjection or in vitro transcription.

Features & Benefits

  • Lot-tested — free of RNase, DNase (endo- and exonuclease) and protease activity
  • Not DEPC-treated — no residual DEPC carryover
  • Ready to use — deionized, filtered and autoclaved in the final container
  • Room-temperature storage and shipping — no cold chain
  • Two formats — one 500 mL bottle, or ten 50 mL bottles to limit contamination risk

Specifications

GradeMolecular biology
PurificationDeionized, 0.22 µm membrane-filtered, autoclaved
TreatmentNot DEPC-treated
pH6.0–8.0
Resistivity≥ 18.2 MΩ·cm at source
Quality controlNo detectable RNase, DNase or protease activity; free of human and E. coli DNA
Pack sizes1 × 500 mL; 10 × 50 mL
StorageRoom temperature (15–30 °C)
ShippingAmbient

For Research Use Only. Not for use in diagnostic procedures.

See the Instructions for Use and Safety Data Sheet tabs for protocols and safety information.

Instructions for Use

AICON-BIO® Nuclease-Free Water (not DEPC-treated) — Instructions for Use

Cat. No. AIDW101 · 1 × 500 mL / 10 × 50 mL · For Research Use Only. Not for use in diagnostic procedures.

1. Description

Molecular biology grade water, deionized, 0.22 µm filtered into the final bottle and autoclaved. Ready to use with no preparation, mixing or autoclaving required. Every lot is tested for RNase, exonuclease and non-specific endonuclease activity. Not DEPC-treated, so there is no residual DEPC to interfere with sensitive applications such as oocyte microinjection or in vitro transcription.

2. Contents and Storage

ComponentQuantityStorage
Nuclease-Free Water1 × 500 mL or 10 × 50 mLRoom temperature

Stable for 12 months from date of manufacture when stored as directed.

3. Typical Use

ApplicationAmount
PCR and qPCR reaction make-upTo final volume
Resuspension of primers and oligonucleotidesAs required
Elution of purified DNA or RNA30–100 µL
Dilution of DNA/RNA samples and standardsAs required
Enzyme reaction make-up (restriction digest, ligation, IVT)To final volume

4. Procedure

  1. Open the bottle only in a clean area; wear gloves to prevent RNase contamination from skin.
  2. Pour or pipette the volume needed using a sterile, nuclease-free pipette or tip. Never pipette directly from the stock bottle with a used tip.
  3. Recap immediately after use.
  4. For RNA work, dispense single-use aliquots into sterile nuclease-free tubes rather than returning to the stock bottle.

5. Notes

  • Not sterile for injection or clinical use; for laboratory research only.
  • Do not autoclave again — repeated autoclaving can introduce contaminants from the vessel.
  • Once opened, the 500 mL bottle should be used within 6 months; the 50 mL bottles are intended for single-project use.
  • Discard any bottle showing turbidity or particulates.

6. Troubleshooting

ProblemPossible causeSolution
RNA degrades after dilutionRNase introduced from tips, gloves or the benchUse filter tips and fresh gloves; aliquot the water; decontaminate surfaces
Unexpected PCR amplification in no-template controlContamination introduced during dispensingOpen a fresh 50 mL bottle; use a dedicated pre-PCR area
Turbidity in the bottleMicrobial growth after a contaminated withdrawalDiscard the bottle; never return unused water

Aicon Biotech Inc. · 8194 SW Durham Rd, Tigard, OR 97224, USA · Tel 503-430-5188 · www.aiconbiotech.com

Safety Data Sheet

Safety Data Sheet — AICON-BIO® Nuclease-Free Water (not DEPC-treated)

Prepared per OSHA HCS (29 CFR 1910.1200) and GHS. Revision date: 2026-11-24 · Version 1.0

Section 1 — Identification

  • Product: AICON-BIO® Nuclease-Free Water (not DEPC-treated), Cat. No. AIDW101
  • Use: Laboratory research reagent. For Research Use Only. Not for use in diagnostic procedures.
  • Supplier: Aicon Biotech Inc. · 8194 SW Durham Rd, Tigard, OR 97224, USA · Tel 503-430-5188 · www.aiconbiotech.com
  • Emergency telephone: 503-430-5188 (business hours)

Section 2 — Hazard(s) Identification

Not a hazardous substance or mixture according to OSHA HCS 2012 / GHS. No pictogram, signal word or hazard statement required. May cause mild eye irritation on contact.

Section 3 — Composition

IngredientCAS No.Concentration
Water7732-18-5100%

Section 4 — First-Aid Measures

  • Eyes: Rinse with water for at least 15 min. Get medical attention if irritation persists.
  • Skin: Wash with soap and water.
  • Inhalation: Move to fresh air.
  • Ingestion: Rinse mouth. Get medical advice if unwell.

Section 5 — Fire-Fighting Measures

Not flammable. Use extinguishing media suitable for the surrounding fire. Thermal decomposition may release carbon and nitrogen oxides.

Section 6 — Accidental Release Measures

Wear gloves and eye protection. Absorb with inert material and dispose of as laboratory waste.

Section 7 — Handling and Storage

Follow good laboratory practice. Storage: Room temperature (15–30 °C). Incompatible: strong oxidizing agents.

Section 8 — Exposure Controls / Personal Protection

No exposure limits established. Safety glasses, nitrile gloves, lab coat. General laboratory ventilation.

Section 9 — Physical and Chemical Properties

Liquid; colorless; viscous (glycerol); miscible with water; not flammable.

Section 10 — Stability and Reactivity

Stable under recommended storage. Avoid strong oxidizers and excessive heat.

Section 11 — Toxicological Information

No data for the mixture; not classified based on component concentrations. No component is listed as a carcinogen by IARC, NTP or OSHA.

Section 12 — Ecological Information

No data. Not expected to be harmful at the quantities used.

Section 13 — Disposal

Dispose of in accordance with local, state and federal regulations.

Section 14 — Transport Information

Not regulated as a dangerous good (DOT, IATA, IMDG).

Section 15 — Regulatory Information

OSHA: not hazardous under 29 CFR 1910.1200. TSCA: for research and development use only, under the supervision of a technically qualified individual.

Section 16 — Other Information

Revision date 2026-11-24, Version 1.0. The information above is believed to be accurate but is not all-inclusive and should be used only as a guide. Aicon Biotech Inc. shall not be held liable for any damage resulting from handling or contact with this product. For Research Use Only. Not for use in diagnostic procedures.