AICON-BIO® dNTP Mix (10 mM each)

Catalog NumberUnit SizeTotal VolumeReactions (50 µL)
AIDN10110 × 1.0 mL (1 pouch)10 mL10,000
AIDN101-2P20 × 1.0 mL (2 pouches)20 mL20,000
AIDN101-5P50 × 1.0 mL (5 pouches)50 mL50,000
AIDN101-10P100 × 1.0 mL (10 pouches)100 mL100,000

10 mM each of dATP, dCTP, dGTP and dTTP. Tubes of 1.0 mL are sealed ten to a pouch; all pack sizes share the same formulation. One tube is sufficient for 1,000 standard 50 µL PCR reactions. Storage: −20 °C.

Price on request — contact info@aiconbiotech.com or 503-430-5188 for a quote.

Product image for reference only; actual product may vary.

SKU: AIDN101 Category:
Description

A ready-to-use premixed aqueous solution of dATP, dCTP, dGTP and dTTP, each at 10 mM (40 mM total). Tubes of 1.0 mL are sealed ten to a pouch and supplied as 1, 2, 5 or 10 pouches per box, so unopened pouches stay frozen and freeze–thaw cycles are kept to a minimum. Every pack size shares the same formulation; one 1.0 mL tube is sufficient for 1,000 standard 50 µL PCR reactions.

Features & Benefits

  • > 99% purity — verified by HPLC
  • Free of nucleases, human and E. coli DNA
  • Sealed pouches of ten 1.0 mL tubes — unopened pouches stay frozen
  • Four pack sizes — 10, 20, 50 or 100 tubes, same formulation throughout
  • Universal — standard PCR, high-fidelity and long PCR, qPCR, RT-PCR, cDNA synthesis, LAMP, sequencing

Specifications

CompositiondATP, dCTP, dGTP, dTTP, 10 mM each in water
Total concentration40 mM
Pack sizesAIDN101: 10 × 1.0 mL (1 pouch) · AIDN101-2P: 20 × 1.0 mL · AIDN101-5P: 50 × 1.0 mL · AIDN101-10P: 100 × 1.0 mL (10 pouches)
Packaging format1.0 mL per tube; 10 tubes per sealed pouch
Purity> 99% (HPLC)
pH7.0 ± 0.5 (25 °C)
Reactions1,000 × 50 µL standard PCR per tube (1 µL per reaction)
Quality controlFree of DNase, RNase, nicking activity, human and E. coli DNA; functionally tested in PCR
StabilityStable through at least 20 freeze–thaw cycles
Storage−20 °C
ShippingBlue ice or dry ice

For Research Use Only. Not for use in diagnostic procedures.

See the Instructions for Use and Safety Data Sheet tabs for protocols and safety information.

Instructions for Use

AICON-BIO® dNTP Mix (10 mM each) — Instructions for Use

Cat. No. AIDN101 / -2P / -5P / -10P · 10 / 20 / 50 / 100 × 1.0 mL · For Research Use Only. Not for use in diagnostic procedures.

1. Description

A ready-to-use premixed aqueous solution of dATP, dCTP, dGTP and dTTP, each at 10 mM (40 mM total). Tubes of 1.0 mL are sealed ten to a pouch and supplied as 1, 2, 5 or 10 pouches per box, so unopened pouches stay frozen and freeze–thaw cycles are kept to a minimum. Every pack size shares the same formulation; one 1.0 mL tube is sufficient for 1,000 standard 50 µL PCR reactions.

2. Kit Contents and Storage

ComponentQuantityStorage
AIDN101 — dNTP Mix, 10 mM each10 × 1.0 mL (1 pouch), 10 mL total, 400 µmol−20 °C
AIDN101-2P — dNTP Mix, 10 mM each20 × 1.0 mL (2 pouches), 20 mL total, 800 µmol−20 °C
AIDN101-5P — dNTP Mix, 10 mM each50 × 1.0 mL (5 pouches), 50 mL total, 2,000 µmol−20 °C
AIDN101-10P — dNTP Mix, 10 mM each100 × 1.0 mL (10 pouches), 100 mL total, 4,000 µmol−20 °C

Stable for 12 months from date of manufacture when stored as directed.

3. Reaction Setup

ComponentVolume
10× PCR Buffer5 µL
dNTP Mix (10 mM each)1 µL (200 µM final each)
Forward primer (10 µM)1 µL
Reverse primer (10 µM)1 µL
Template DNA1–100 ng
DNA polymerase0.5–1 U
Nuclease-free waterto 50 µL

4. Reaction Conditions

StepTemperatureTime
Initial denaturation95 °C2–5 min
Denaturation (25–35 cycles)95 °C30 s
Annealing50–65 °C30 s
Extension72 °C1 min per kb
Final extension72 °C5–10 min
Hold4 °C∞

5. Procedure

  1. Take one pouch from the box, remove a single tube and thaw it on ice; keep the remaining tubes and any unopened pouches frozen at −20 °C.
  2. Vortex briefly and spin down before each use — nucleotides settle during storage.
  3. Add 1 µL per 50 µL reaction for a final concentration of 200 µM each (0.8 mM total). This suits most standard PCR.
  4. For high-fidelity and proofreading enzymes, reduce to 10–50 µM each final; for long-range PCR use 300–500 µM each.
  5. For qPCR and RT-PCR, follow the polymerase supplier’s recommended dNTP concentration.
  6. Return the working tube to −20 °C immediately after use.

6. Notes

  • Final dNTP and Mg²⁺ concentrations are linked: every 200 µM of total dNTP chelates roughly 200 µM Mg²⁺. If you raise the dNTP concentration, raise MgCl₂ to match.
  • Do not leave the mix at room temperature for extended periods; dNTPs hydrolyze to dNDP and dNMP.
  • Aliquot a working tube into smaller volumes if you run many small reactions — this limits freeze–thaw further. Keep unopened pouches sealed until needed.
  • For dUTP-containing or UNG-based workflows, use a dUTP mix instead of this product.

7. Troubleshooting

ProblemPossible causeSolution
Weak or no productdNTPs degraded by repeated freeze–thawOpen a fresh 1 mL tube; aliquot in future
Smeared or nonspecific bandsdNTP or Mg²⁺ too highReduce to 200 µM each; titrate MgCl₂ from 1.5 mM
Low fidelity / mutationsdNTP concentration too high for proofreading enzymeLower to 10–50 µM each final
Precipitate in the tubeNormal after thawingVortex and spin briefly before pipetting

Aicon Biotech Inc. · 8194 SW Durham Rd, Tigard, OR 97224, USA · Tel 503-430-5188 · www.aiconbiotech.com

Safety Data Sheet

Safety Data Sheet — AICON-BIO® dNTP Mix (10 mM each)

Prepared per OSHA HCS (29 CFR 1910.1200) and GHS. Revision date: 2026-11-24 · Version 1.0

Section 1 — Identification

  • Product: AICON-BIO® dNTP Mix (10 mM each), Cat. No. AIDN101 / -2P / -5P / -10P
  • Use: Laboratory research reagent. For Research Use Only. Not for use in diagnostic procedures.
  • Supplier: Aicon Biotech Inc. · 8194 SW Durham Rd, Tigard, OR 97224, USA · Tel 503-430-5188 · www.aiconbiotech.com
  • Emergency telephone: 503-430-5188 (business hours)

Section 2 — Hazard(s) Identification

Not a hazardous substance or mixture according to OSHA HCS 2012 / GHS. No pictogram, signal word or hazard statement required. May cause mild eye irritation on contact.

Section 3 — Composition

IngredientCAS No.Concentration
2′-Deoxyadenosine 5′-triphosphate, sodium salt (dATP)1927-31-7~0.6%
2′-Deoxycytidine 5′-triphosphate, sodium salt (dCTP)102783-51-7~0.6%
2′-Deoxyguanosine 5′-triphosphate, sodium salt (dGTP)93919-41-6~0.6%
Thymidine 5′-triphosphate, sodium salt (dTTP)18423-43-3~0.6%
Water7732-18-5Balance

Section 4 — First-Aid Measures

  • Eyes: Rinse with water for at least 15 min. Get medical attention if irritation persists.
  • Skin: Wash with soap and water.
  • Inhalation: Move to fresh air.
  • Ingestion: Rinse mouth. Get medical advice if unwell.

Section 5 — Fire-Fighting Measures

Not flammable. Use extinguishing media suitable for the surrounding fire. Thermal decomposition may release carbon and nitrogen oxides.

Section 6 — Accidental Release Measures

Wear gloves and eye protection. Absorb with inert material and dispose of as laboratory waste.

Section 7 — Handling and Storage

Follow good laboratory practice. Storage: −20 °C. Incompatible: strong oxidizing agents.

Section 8 — Exposure Controls / Personal Protection

No exposure limits established. Safety glasses, nitrile gloves, lab coat. General laboratory ventilation.

Section 9 — Physical and Chemical Properties

Liquid; colorless; viscous (glycerol); miscible with water; not flammable.

Section 10 — Stability and Reactivity

Stable under recommended storage. Avoid strong oxidizers and excessive heat.

Section 11 — Toxicological Information

No data for the mixture; not classified based on component concentrations. No component is listed as a carcinogen by IARC, NTP or OSHA.

Section 12 — Ecological Information

No data. Not expected to be harmful at the quantities used.

Section 13 — Disposal

Dispose of in accordance with local, state and federal regulations.

Section 14 — Transport Information

Not regulated as a dangerous good (DOT, IATA, IMDG).

Section 15 — Regulatory Information

OSHA: not hazardous under 29 CFR 1910.1200. TSCA: for research and development use only, under the supervision of a technically qualified individual.

Section 16 — Other Information

Revision date 2026-11-24, Version 1.0. The information above is believed to be accurate but is not all-inclusive and should be used only as a guide. Aicon Biotech Inc. shall not be held liable for any damage resulting from handling or contact with this product. For Research Use Only. Not for use in diagnostic procedures.

Reviews

There are no reviews yet.

Only logged in customers who have purchased this product may leave a review.