AICON-BIO® Listeria monocytogenes Real-time PCR Kit

$338.00$672.00

The AICON-BIO® Listeria monocytogenes Real-time PCR Kit provides a fast, accurate and reliable method for detecting Listeria monocytogenes nucleic acid using real-time PCR technology. Validated on tissue, whole blood, serum from livestock, poultry. The lyophilized one-step qPCR mix stays stable during transport and storage without a cold chain. Available in 48T and 96T.

Description

The AICON-BIO® Listeria monocytogenes PCR Kit is a lyophilized, one-step real-time PCR assay for the qualitative detection of L. monocytogenes nucleic acid in tissue, whole blood, serum and swab samples from livestock and poultry. Supplied in 48T and 96T, it runs on any real-time PCR instrument and returns a result in about 75 minutes.

Why this kit

Why laboratories choose this Listeria monocytogenes PCR kit


AmbientNo cold chain to runLyophilized reaction tubes ship and handle at ambient temperature — no dry ice, no thaw cycles.
~75 minSample-to-answerA single 45-cycle FAM programme; results read automatically by the instrument software.
2Pipetting stepsReconstitute, add 5 µL template, run. Primers, probe, enzyme and dNTPs are already in the tube.
OpenAny qPCR platformABI, Bio-Rad, Roche, QIAGEN, Agilent and others — no proprietary instrument required.

Intended use

What the Listeria monocytogenes PCR Kit detects


Real-time fluorescent PCR for the qualitative in vitro detection of Listeria monocytogenes nucleic acid in clinical samples from livestock, poultry and other animals, supporting the clinical diagnosis of listeriosis.

Clinical context. Listeriosis — 'circling disease' in ruminants, plus abortion and septicaemia; a foodborne zoonosis with high human case-fatality.

Target species & specimens

TargetL. monocytogenes
Animal speciesLivestock, Poultry
Specimen typesTissue, Whole blood, Serum, Swab
Assay noteSpecies-specific for Listeria monocytogenes; also applicable to environmental and food-chain monitoring workflows.

Specifications

Technical data


Catalogue numberAIAM0001
Pack sizes48T and 96T
MethodOne-step real-time PCR, TaqMan®-style hydrolysis probe
Reagent formatLyophilized, room-temperature-stable reaction tubes
Fluorophore / channelFAM
Reaction volume25 µL
Template input5 µL extracted nucleic acid
Instrument compatibilityAll major real-time PCR platforms — ABI, Bio-Rad, Roche LightCycler, QIAGEN Rotor-Gene, Agilent, Thermo. Add reference dye where the manufacturer recommends it.
Nucleic-acid extractionAny commercial extraction kit; not supplied
Shelf life12 months
Document referenceIFU-Listeria monocytogenes-RT-V1.0
Country of originMade in USA

Kit contents

What is in the Listeria monocytogenes PCR kit box


ComponentQuantityComposition
L. monocytogenes Real-Time PCR Lyophilized Tube8 tests/bag × 12Target-specific primers, probe, enzyme and dNTPs
Lyophilized Reconstitution Buffer450 µL/tube × 6Buffer for reconstituting the reaction tubes
Positive Control1 tubeSynthetic plasmid carrying the target sequence
Negative Control1 tubeNuclease-free control material
Instructions for Use1 copySupplied with every kit

Quantities shown are for the 96T configuration; the 48T kit contains half quantities.

Workflow

Four steps from extract to result


  1. Extract nucleic acid with any commercial extraction kit.
  2. Reconstitute one lyophilized tube with the supplied buffer, mix, spin briefly.
  3. Combine 20 µL reconstituted reagent + 5 µL template (or control) = 25 µL reaction.
  4. Run the FAM-channel cycling programme; the instrument software reads the result.

Thermal cycling programme

CyclesTemperatureTime
1 cycle50 °C10 min
1 cycle95 °C3 min
45 cycles95 °C15 sec
 60 °C (FAM read)30 sec

Set the reaction volume to 25 µL and select the FAM channel. On ABI systems leave the analysis threshold at its default value of 0.2.

Result interpretation

Reading the run


Ct valueInterpretation
Ct < 37Positive
37 ≤ Ct < 45Suspicious — retest with a fresh sample
No CtNegative
Run validity. The negative control must show no amplification and the positive control a clear amplification curve. If the negative control amplifies, suspect contamination and repeat; if the positive control fails, the run is invalid.

Sample handling

Specimen collection & storage


TissueGreen-bean-sized piece into a 1.5 mL tube with 500 µL preservation solution; grind with a disposable pestle; centrifuge 1 min; take the supernatant.
Whole bloodCollect into an EDTA anticoagulant tube.
SerumAllow the blood to clot or centrifuge at low speed; collect the supernatant.
SwabSmear the sampling site, place the tip into a 1.5 mL tube with 500 µL preservation solution; grind a few seconds; centrifuge 1 min; take the supernatant.

Storage & stability

Lyophilized reagents ship at room temperature — no cold chain required. On arrival, store the lyophilized reagents at −20 °C; liquid reagents below 4 °C. Stable until the expiry date printed on the label. Keep the tubes sealed in their aluminium pouches to prevent moisture uptake and bring them to room temperature before use. Once reconstituted, seal tightly, store at −20 °C and use within one month.

Related tests

Other kits for the same animals


See the full range in Animal Disease Testing. Disease definitions and notifiable-disease status follow WOAH, the World Organisation for Animal Health.

For Research Use Only. Not for use in diagnostic procedures. Results should be interpreted together with clinical findings, epidemiological context and other laboratory results. Performance characteristics have not been established for regulated diagnostic testing in every jurisdiction — contact info@aiconbiotech.com for the regulatory status in your market.
Additional information
Weight N/A
Dimensions N/A
SIZE

48T

,

96T

Reviews

There are no reviews yet.

Only logged in customers who have purchased this product may leave a review.