AICON-BIO® Avian Influenza Virus H7 (H7-HPAI) Real-time PCR Kit

$338.00$672.00

The AICON-BIO® Avian Influenza Virus H7 (H7-HPAI) Real-time PCR Kit provides a fast, accurate and reliable method for detecting avian influenza virus subtype H7 nucleic acid using real-time PCR technology. The lyophilized one-step qPCR mix stays stable during transport and storage without a cold chain, and contains primers, probes, enzyme and dNTPs in a single tube. Available in 48T and 96T.

SKU: AIDB0004 Category:
Description

Why this kit

Built for field-realistic veterinary laboratories


AmbientNo cold chain to run
Lyophilized reaction tubes ship and handle at ambient temperature — no dry ice, no thaw cycles.
~75 minSample-to-answer
A single 45-cycle FAM programme; results read automatically by the instrument software.
2Pipetting steps
Reconstitute, add 5 µL template, run. Primers, probe, enzyme and dNTPs are already in the tube.
OpenAny qPCR platform
ABI, Bio-Rad, Roche, QIAGEN, Agilent and others — no proprietary instrument required.

Intended use

What the Avian Influenza Virus H7 (H7-HPAI) kit detects


The AICON-BIO® Avian Influenza Virus H7 Real-time PCR Kit uses real-time PCR technology and a premixed freeze-drying method to detect avian influenza virus subtype H7 nucleic acid. H7 is one of only two haemagglutinin subtypes able to acquire a highly pathogenic phenotype; low-pathogenic H7 viruses circulating in poultry can mutate into highly pathogenic forms that kill most of a flock within 48 hours.

H7 infections are WOAH-notifiable, and several H7 subtypes — H7N9 in particular — have caused serious human disease. Early subtype identification is what allows control measures to begin before the virus becomes highly pathogenic. The Kit qPCR mix (lyophilized) contains primers, probes, enzyme and dNTPs in one tube.

Clinical context. H7 — LPAI to HPAI conversion; zoonotic risk.

Target species & specimens

TargetAvian Influenza Virus H7 (H7-HPAI)
Animal speciesPoultry
Specimen typesOropharyngeal / cloacal swab, tissue

Specifications

Technical data


Catalogue numberAIDB0004
Pack sizes48T and 96T
MethodOne-step real-time PCR, TaqMan®-style hydrolysis probe
Reagent formatLyophilized, room-temperature-stable reaction tubes
Fluorophore / channelFAM
Reaction volume25 µL
Template input5 µL extracted nucleic acid
Instrument compatibilityAll major real-time PCR platforms — ABI, Bio-Rad, Roche LightCycler, QIAGEN Rotor-Gene, Agilent, Thermo. Add reference dye where the manufacturer recommends it.
Nucleic-acid extractionAny commercial extraction kit; not supplied
Shelf life12 months
Country of originMade in USA

Kit contents

What is in the box


ComponentQuantityComposition
Avian Influenza Virus H7 (H7-HPAI) Real-Time PCR Lyophilized Tube8 tests/bag × 12Target-specific primers, probe, enzyme and dNTPs
Lyophilized Reconstitution Buffer450 µL/tube × 6Buffer for reconstituting the reaction tubes
Positive Control1 tubeSynthetic plasmid carrying the target sequence
Negative Control1 tubeNuclease-free control material
Instructions for Use1 copySupplied with every kit

Quantities shown are for the 96T configuration; the 48T kit contains half quantities.

Workflow

Four steps from extract to result


  1. Extract nucleic acid with any commercial extraction kit.
  2. Reconstitute one lyophilized tube with the supplied buffer, mix, spin briefly.
  3. Combine 20 µL reconstituted reagent + 5 µL template (or control) = 25 µL reaction.
  4. Run the FAM-channel cycling programme; the instrument software reads the result.

Thermal cycling programme

CyclesTemperatureTime
1 cycle50 °C10 min
1 cycle95 °C3 min
45 cycles95 °C15 sec
 60 °C (FAM read)30 sec

Set the reaction volume to 25 µL and select the FAM channel. On ABI systems leave the
analysis threshold at its default value of 0.2.

Result interpretation

Reading the run


Ct valueInterpretation
Ct < 37Positive
37 ≤ Ct < 45Suspicious — retest with a fresh sample
No CtNegative
Run validity. The negative control must show
no amplification and the positive control a clear amplification curve. If the negative control
amplifies, suspect contamination and repeat; if the positive control fails, the run is invalid.

Sample handling

Specimen collection & storage


TissueGreen-bean-sized piece into a 1.5 mL tube with 500 µL preservation solution; grind with a disposable pestle; centrifuge 1 min; take the supernatant.
Whole bloodCollect into an EDTA anticoagulant tube.
SerumAllow the blood to clot or centrifuge at low speed; collect the supernatant.
SwabSmear the sampling site, place the tip into a 1.5 mL tube with 500 µL preservation solution; grind a few seconds; centrifuge 1 min; take the supernatant.

Storage & stability

Lyophilized reagents ship at room temperature — no cold chain required. On arrival, store the lyophilized reagents at −20 °C; liquid reagents below 4 °C. Stable until the expiry date printed on the label. Keep the tubes sealed in their aluminium pouches to prevent moisture uptake and bring them to room temperature before use. Once reconstituted, seal tightly, store at −20 °C and use within one month.

For Research Use Only. Not for use in diagnostic procedures.
Results should be interpreted together with clinical findings, epidemiological context and other
laboratory results. Performance characteristics have not been established for regulated
diagnostic testing in every jurisdiction — contact
info@aiconbiotech.com for the regulatory status in
your market.
Additional information
Weight 2 kg
Dimensions 15 × 18 × 20 cm
Size

48T

,

96T

Reviews

There are no reviews yet.

Only logged in customers who have purchased this product may leave a review.