AICON-BIO™ GS-GelRed Nucleic Acid Gel Stain (10,000×)
$99.00
| Catalog Number | Unit Size |
| AIGL802 | 500 µL |
Storage: Room temperature, protect from light
Product image for reference only; actual product may vary.
A sensitive, low-hazard red fluorescent nucleic acid gel stain supplied as a 10,000× solution. It replaces ethidium bromide for staining dsDNA, ssDNA and RNA in agarose and polyacrylamide gels, with UV or blue-light excitation and the standard EtBr filter.
Features & Benefits
- Safer alternative to EtBr — designed to be cell-membrane impermeable
- Sensitive — comparable to or better than EtBr
- Flexible — pre-cast (in-gel) or post-staining
- Standard optics — UV transilluminator with EtBr filter; also blue light
Specifications
| Concentration | 10,000× in water |
| Excitation / emission | ~300 nm (UV) and ~500 nm / ~600 nm |
| Pre-cast use | 5 µL per 50 mL gel (1:10,000) |
| Post-stain use | 3× (1:3,300) in 0.1 M NaCl, 30 min |
| Detects | dsDNA, ssDNA, RNA |
| Pack size | 500 µL (≈ 5 L of gel) |
| Storage | Room temperature, protect from light |
| Shipping | Ambient temperature |
For Research Use Only. Not for use in diagnostic procedures.
See the Instructions for Use and Safety Data Sheet tabs for protocols and safety information.
AICON-BIO™ GS-GelRed Nucleic Acid Gel Stain (10,000×) — Instructions for Use
Cat. No. AIGL802 · 500 µL · For Research Use Only. Not for use in diagnostic procedures.
1. Description
A sensitive, low-hazard red fluorescent nucleic acid gel stain supplied as a 10,000× solution. It replaces ethidium bromide for staining dsDNA, ssDNA and RNA in agarose and polyacrylamide gels, with UV or blue-light excitation and the standard EtBr filter.
2. Kit Contents and Storage
| Component | Quantity | Storage |
|---|---|---|
| GS-GelRed Nucleic Acid Gel Stain, 10,000× | 500 µL | Room temperature, protect from light |
Stable for 12 months from date of manufacture when stored as directed.
3. Preparation
| Item | Amount |
|---|---|
| Pre-cast: molten agarose | 50 mL |
| GS-GelRed 10,000× | 5 µL |
| Post-stain: 0.1 M NaCl (or water) | 50 mL with 15 µL GS-GelRed (3×) |
4. Procedure
- Pre-cast: add 5 µL stain per 50 mL molten agarose (~60 °C), mix gently and pour.
- Post-stain: after electrophoresis, soak the gel in 3× stain solution for 30 min with gentle shaking, protected from light.
- Image on a UV transilluminator with the standard EtBr filter, or a blue-light imager.
5. Notes
- Post-staining gives the most accurate sizing for large fragments.
- Dispose of used stain according to local regulations; collect as chemical waste.
- Protect from light.
6. Troubleshooting
| Problem | Possible cause | Solution |
|---|---|---|
| Weak signal | Too little stain | Use post-staining or increase to 1:5,000 pre-cast |
| Band shift or smearing | Excess dye in pre-cast gel | Use post-staining for accurate sizing |
Aicon Biotech Inc. · 8194 SW Durham Rd, Tigard, OR 97224, USA · Tel 503-430-5188 · www.aiconbiotech.com
Safety Data Sheet — AICON-BIO™ GS-GelRed Nucleic Acid Gel Stain (10,000×)
Prepared per OSHA HCS (29 CFR 1910.1200) and GHS. Revision date: 2026-11-24 · Version 1.0
Section 1 — Identification
- Product: AICON-BIO™ GS-GelRed Nucleic Acid Gel Stain (10,000×), Cat. No. AIGL802
- Use: Laboratory research reagent. For Research Use Only. Not for use in diagnostic procedures.
- Supplier: Aicon Biotech Inc. · 8194 SW Durham Rd, Tigard, OR 97224, USA · Tel 503-430-5188 · www.aiconbiotech.com
- Emergency telephone: 503-430-5188 (business hours)
Section 2 — Hazard(s) Identification
Not a hazardous substance or mixture according to OSHA HCS 2012 / GHS. No pictogram, signal word or hazard statement required. May cause mild eye irritation on contact.
Section 3 — Composition
| Ingredient | CAS No. | Concentration |
|---|---|---|
| Nucleic acid stain dye (proprietary) | — | < 1% |
| Water | 7732-18-5 | Balance |
Section 4 — First-Aid Measures
- Eyes: Rinse with water for at least 15 min. Get medical attention if irritation persists.
- Skin: Wash with soap and water.
- Inhalation: Move to fresh air.
- Ingestion: Rinse mouth. Get medical advice if unwell.
Section 5 — Fire-Fighting Measures
Not flammable. Use extinguishing media suitable for the surrounding fire. Thermal decomposition may release carbon and nitrogen oxides.
Section 6 — Accidental Release Measures
Wear gloves and eye protection. Absorb with inert material and dispose of as laboratory waste.
Section 7 — Handling and Storage
Follow good laboratory practice. Storage: Room temperature, protect from light. Incompatible: strong oxidizing agents.
Section 8 — Exposure Controls / Personal Protection
No exposure limits established. Safety glasses, nitrile gloves, lab coat. General laboratory ventilation.
Section 9 — Physical and Chemical Properties
Red-orange liquid; miscible with water; not flammable.
Section 10 — Stability and Reactivity
Stable under recommended storage. Avoid strong oxidizers and excessive heat.
Section 11 — Toxicological Information
No data for the mixture; not classified based on component concentrations. No component is listed as a carcinogen by IARC, NTP or OSHA.
Section 12 — Ecological Information
No data. Not expected to be harmful at the quantities used.
Section 13 — Disposal
Dispose of in accordance with local, state and federal regulations.
Section 14 — Transport Information
Not regulated as a dangerous good (DOT, IATA, IMDG).
Section 15 — Regulatory Information
OSHA: not hazardous under 29 CFR 1910.1200. TSCA: for research and development use only, under the supervision of a technically qualified individual.
Section 16 — Other Information
Revision date 2026-11-24, Version 1.0. The information above is believed to be accurate but is not all-inclusive and should be used only as a guide. Aicon Biotech Inc. shall not be held liable for any damage resulting from handling or contact with this product. For Research Use Only. Not for use in diagnostic procedures.
Only logged in customers who have purchased this product may leave a review.